Ultimate Solution Hub

Attune Revision Knee System Preparation For Femoral Stem Implantation

attuneв ў revision knee system Products Depuy Synthes
attuneв ў revision knee system Products Depuy Synthes

Attuneв ў Revision Knee System Products Depuy Synthes This surgical technique provides guidelines for the implantation of the attune® revision knee system. attune revision knee system fixed bearing (fb) implants include the following components: attune revision femoral component. attune revision fixed bearing insert. The attune™ revision knee system provides a modern revision knee system scientifically designed for stability in motion™ that more closely matches the kinematics of the natural knee to allow for functional knee restoration and improve patient satisfaction. 1,2 the system is designed to simplify the complex, with joint line restoration and.

attuneв revision knee system Depuy Synthes J J Medtech Nz
attuneв revision knee system Depuy Synthes J J Medtech Nz

Attuneв Revision Knee System Depuy Synthes J J Medtech Nz At the end of this video, you should be able to describe the surgical technique steps for preparing the femur during a revision total knee arthroplasty procedure. this content is intended for health care professionals in the united states. Boss preparation. remove the femoral reamer bushing. assemble the appropriate cemented stem trial to the femoral boss reamer and attach the modular stop to the most proximal line on the femoral boss reamer. seat the reamer to the stop. remove all instruments except the cut through trial and pins. 2. Instruments surgical techniqueintroductionthis surgical technique provides guidelines for the implantation of the attune® knee system family of knee im. attune knee system implants are available in four configurations: posterior stabilized fixed bearing (ps fb), posterior stabilized rotating platform (ps rp), cruciate retaining fixed bearing. 1. primary resections using the attune®knee system intuition™ instrumentation. place the respective cut through trial on the resected femur assemble the reamer tower and bushing. 2 5. 5. short cemented stem workflow. femoral orkflows. resect the box. ream using the selected cemented femoral stem reamer and boss reamer.

attune Revision Knee System Preparation For Femoral Stem Implantation
attune Revision Knee System Preparation For Femoral Stem Implantation

Attune Revision Knee System Preparation For Femoral Stem Implantation Instruments surgical techniqueintroductionthis surgical technique provides guidelines for the implantation of the attune® knee system family of knee im. attune knee system implants are available in four configurations: posterior stabilized fixed bearing (ps fb), posterior stabilized rotating platform (ps rp), cruciate retaining fixed bearing. 1. primary resections using the attune®knee system intuition™ instrumentation. place the respective cut through trial on the resected femur assemble the reamer tower and bushing. 2 5. 5. short cemented stem workflow. femoral orkflows. resect the box. ream using the selected cemented femoral stem reamer and boss reamer. Select attune™ knee system tibial insert trial that matches femoral size and style (cr or ps for either rotating platform or fixed bearing), and the appropriate thickness (5 mm, 6 mm, 7 mm, 8 mm, 10 mm, 12 mm, 14 mm and 16 mm for cr and ps, and in addition 18 mm for ps, for core sizes 3 8). At the end of this video, you should be able to describe the surgical technique steps for preparing the femur during a revision total knee arthroplasty procedure. attune revision knee system: preparation for femoral stem implantation with ryan nunley, md | johnson & johnson institute.

Comments are closed.