Ultimate Solution Hub

Pdf Surgical Technique Cortical в 4 Depuy Synthes Tfn вђ Titanium

pdf surgical technique cortical в 4 depuy synthes tfnо
pdf surgical technique cortical в 4 depuy synthes tfnо

Pdf Surgical Technique Cortical в 4 Depuy Synthes Tfnо 10 surgical technique • tfn advanced™ proximal femoral nailing system (tfna) preparation 4. determine nail length instrument 03.037.006 radiographic ruler move the image intensifi er to the distal femur, place the proximal end of the radiographic ruler at the skin mark, and take an ap image of the distal femur. verify fracture reduction. Tfn – titanium trochanteric fixation nail system technique guide synthes page 16 insert the guide wire through the protection sleeve and drill sleeve. confirm guide wire placement in both the ap and lateral planes. insert to a depth of approximately 15 cm. re move the drill sleeve.

Tous Les Catalogues Et Fiches Techniques pdf depuy synthes
Tous Les Catalogues Et Fiches Techniques pdf depuy synthes

Tous Les Catalogues Et Fiches Techniques Pdf Depuy Synthes The tfn advanced nailing system is a part of the advanced nailing system from depuy synthes and has features that allow surgeons to address proximal femur fractures. the system includes: long nails – diameters: 9 12, & 14 mm. lengths ranging from: 260 – 480 mm. short nails – diameters: 9 12 mm. Results: 222 patients met inclusion criteria (123 using depuy synthes trochanteric fixation nail proximal femoral nailing system (tfn) with static locking; 65 tfn with dynamic locking; 23 using. Synthes titanium trochanteric fixation nail system—screw option technique guide page 13 insert the guide wire through the protection sleeve and wire guide. confirm guide wire placement in both the ap and lateral planes. insert to a depth of approximately 15 cm. remove the wire guide. It is recommended to use 3 ml of cement for augmentation.precaution: the working time for traumacem v injectable bone cement. t room temperature (20 °c) is approximately 27 minutes. at. ody temperature (37 °c) the setting time is 15 minutes. after last cement injection, the patient should remain i.

Product Rationale And surgical technique depuy synthes pdf Catalogs
Product Rationale And surgical technique depuy synthes pdf Catalogs

Product Rationale And Surgical Technique Depuy Synthes Pdf Catalogs Synthes titanium trochanteric fixation nail system—screw option technique guide page 13 insert the guide wire through the protection sleeve and wire guide. confirm guide wire placement in both the ap and lateral planes. insert to a depth of approximately 15 cm. remove the wire guide. It is recommended to use 3 ml of cement for augmentation.precaution: the working time for traumacem v injectable bone cement. t room temperature (20 °c) is approximately 27 minutes. at. ody temperature (37 °c) the setting time is 15 minutes. after last cement injection, the patient should remain i. Titanium sternal fixation system construct strength comparison constructs loaded in tension in lateral direction. all tests were performed on 10 mm thick composite polyurethane foam test blocks composed of an inner (cancellous) core of 5 lb ft 3 polyurethane foam with a 1.25 mm thick (cortical) shell of 10 lb ft 3 polyurethane foam laminated to the exterior.*. Depuy synthes tfn advanced™ proximal femoral nailing system (tfna) • page 4 of 5 results varus deformation and femoral head rotation around the neck axis were measured. results of the testing are summarized below, and comparison of the groups are displayed in figure 7. • the helical blade is comparable to the integrated.

Comments are closed.