Ultimate Solution Hub

Tfn Trochanteric Fixation Nail Intramedullary Hip Nail Youtube

tfn Trochanteric Fixation Nail Intramedullary Hip Nail Youtube
tfn Trochanteric Fixation Nail Intramedullary Hip Nail Youtube

Tfn Trochanteric Fixation Nail Intramedullary Hip Nail Youtube Explanation of how the tfn works. David s. wellman, md, and ethan jensen, pa c, lead a video detailing surgical first assist methods and approaches involved in the fixation of a hip fracture.

Titanium trochanteric fixation nail System tfn вђ Welcome To Sys
Titanium trochanteric fixation nail System tfn вђ Welcome To Sys

Titanium Trochanteric Fixation Nail System Tfn вђ Welcome To Sys The gamma4 trochanteric nail is a hip fracture solution for fixation of stable and unstable intertrochantric fractures.learn more: stryker us. Usually, this appointment is made when you schedule surgery. if you do not have one, please call the office to schedule at 775 786 3040 as soon as you can. you will be seen at 2 weeks, 6 weeks and 3 months from surgery where the provider will examine you and x rays will be taken to follow bone healing. The tfn is made of titanium alloy (ti 6ai 7nb). the tfn is available in two sizes, short in lengths of 170 mm and 235 mm, and long in lengths of 300460 mm. additional to the existing diameters of 10 mm, 11 mm and 12 mm, the tfn is now also available in 14 mm diameter. the 11.0 mm titanium helical blade provides improved resistance to varus. Notable features of the tfn a carried over from the tfn pfna lines include varying nail lengths (170 mm up to 480 mm) and diameters (9 mm up to 12 mm), options for either a helical blade or lag screw for cephalo medullary fixation (tfn only) and the option for head–neck augmentation with bone cement via a specially designed system that is.

trochanteric Femoral nail
trochanteric Femoral nail

Trochanteric Femoral Nail The tfn is made of titanium alloy (ti 6ai 7nb). the tfn is available in two sizes, short in lengths of 170 mm and 235 mm, and long in lengths of 300460 mm. additional to the existing diameters of 10 mm, 11 mm and 12 mm, the tfn is now also available in 14 mm diameter. the 11.0 mm titanium helical blade provides improved resistance to varus. Notable features of the tfn a carried over from the tfn pfna lines include varying nail lengths (170 mm up to 480 mm) and diameters (9 mm up to 12 mm), options for either a helical blade or lag screw for cephalo medullary fixation (tfn only) and the option for head–neck augmentation with bone cement via a specially designed system that is. A total of 42 (79.2%) had a 31.a2 fracture (21 in the long nail group and 21 in the short nail group) and 11 (20.8%) had a 31.a3 fracture (6 in long nail group and 5 in the short nail group). surgical time was significantly longer (p<0.05) in the long nail group (an average of 81.38±12.01 min), compared with the short nail group (53.11±8.36 min). Since the 1940s, intertrochanteric fractures have been treated with intramedullary nailing, and intramedullary fixation became standard treatment for femoral shaft fractures in the 1950s. in 1967, zickel 2,3 produced good results with intramedullary nailing for fixation of proximal femur fractures. antegrade nailing became the standard fixation.

intramedullary nail For Intertrochanteric hip Fracture Bios Pics
intramedullary nail For Intertrochanteric hip Fracture Bios Pics

Intramedullary Nail For Intertrochanteric Hip Fracture Bios Pics A total of 42 (79.2%) had a 31.a2 fracture (21 in the long nail group and 21 in the short nail group) and 11 (20.8%) had a 31.a3 fracture (6 in long nail group and 5 in the short nail group). surgical time was significantly longer (p<0.05) in the long nail group (an average of 81.38±12.01 min), compared with the short nail group (53.11±8.36 min). Since the 1940s, intertrochanteric fractures have been treated with intramedullary nailing, and intramedullary fixation became standard treatment for femoral shaft fractures in the 1950s. in 1967, zickel 2,3 produced good results with intramedullary nailing for fixation of proximal femur fractures. antegrade nailing became the standard fixation.